This sample project designs members of a multi-story steel building in Calcs.com to the Eurocodes (EN 1990, EN 1991 and EN 1993-1-1) with the UK National Annex. It follows the dimensions and loading of SCI P387, so each member’s demand and capacity can be checked against that publication. It covers a restrained and an unrestrained floor joist (EX1 and EX2), an interior column (EX5) and a roof truss (EX6). To open it, click the “See Sample Projects” button at the top of the Project Page. Reference: Steel Building Design: Worked examples for students © 2009 The Steel Construction Institute P387. Available at SteelSCI.com.

Building geometry

3D frame of the steel building with the members designed in this project highlighted: restrained floor joist EX1, unrestrained floor joist EX2, interior column EX5 and roof truss EX6 Typical section A-A from SCI P387 with the floor joists (1, 2), interior column (5) and roof truss (6) circled, showing an 8 m and 6 m bay, a 5 m ground story and 4.5 m upper stories The project uses these Calcs.com features:

Set up the project defaults

Project Defaults hold the EN 1990 and EN 1991 settings (basis of structural design and loading) and any National Annex settings used throughout the project. See Project Defaults for Europe. This project uses:
1

Partial and reduction factors, and combinations of actions

See SCI P387 Cl 3.2.1.
  • Partial and reduction factors: use the Calcs.com defaults.
  • Strength combination of actions: the UK NA requires the Eq 6.10a/b load combinations and a reduction factor ξ=0.925\xi = 0.925.
  • Serviceability combinations: the UK NA does not consider dead load in serviceability load combinations. Select “Custom” and amend the dead load factors.
2

Deflection limits

See SCI P387 Cl 3.2.2.
  • Steel deflection limits: use the Calcs.com defaults, which are consistent with the UK for characteristic combinations. Override frequent and quasi-permanent to Span / 1, meaning no checks are required per UK NA.2.23.
  • Absolute deflection limits: not used in SCI P387 (usually deflection is limited by plaster or other building restrictions), so they are increased to 100 mm.
  • Timber and concrete deflection limits: leave blank, as they are not used in this project.
3

Default loads

See the individual examples.
  • Floor default loads: Floor Joists EX1 and EX2 use a floor self-weight of 3.7 kPa and an imposed floor load of 3.3 kPa.
  • Roof and wall default loads: not used in this project, so left as is.
4

Default building geometry

  • Floor heights: set to 5000 mm, as used in SCI P387. For the single column calculated here this saves little time, but in a real project there would be several columns with different geometry and loading.
Project Defaults page for the sample project, with the deflection limits, default building geometry, default loads, and partial and reduction factor and load combination sections highlighted

Design the floor joists (EX1 and EX2)

Plan at level 1 from SCI P387 with the two floor joist spans circled: 1 is the restrained joist and 2 is the unrestrained joist
Because the project has default loads and load widths, they are applied automatically to each Floor Joist calculation as distributed loads with load widths. The load combinations and factors from Project Defaults are checked in each joist calculation too, with force and deflection graphs for each combination.
A typical restrained and unrestrained floor joist are analyzed and designed in Calcs.com, following the SCI P387 procedure. For details of the calculator, see Design a Steel Beam to EN 1993 (Eurocode 3). The “Floor Joist” sub-category is selected so the default loading is transferred. Enter:
1

Geometry and steel grade

  • Steel grades: for EX1, select EN 10025-2 UK Prod Std, Gr. S275 (3 mm < t <= 16 mm). For EX2, select (16 mm < t <= 40 mm). Calcs.com also provides simplified grades per EN 1993, but the UK NA does not allow them.
  • Length between lateral restraints: 0 for full restraint (EX1) and 6000 mm for the unrestrained joist (EX2).
  • Pinned supports: add one at each end of the beam.
2

Loads (EN 1991)

  • Default loads: applied automatically from Project Defaults.
  • Self-weight: “No” for the restrained beam (EX1). “Yes” for the unrestrained beam (EX2), plus an additional 1.78 kN/m dead load to give a total strength UDL = 60.8kNm per SCI P387.
  • Building category: Category “B: Office Areas”.
  • Leave the other defaults: load is applied through the shear center and from the top.
3

Design criteria

All deflection limits come from Project Defaults.
4

ULS: buckling resistance of uniform member in bending (EN 1993-1-1:2005 Cl 6.3.2), EX2 only

  • Equivalent uniform moment factor C1C_1: 1.13, consistent with SCI P387.
  • C2C_2 and kk: leave as is.
Then check the key results in the summary section at the top right.

Restrained beam (EX1)

Unrestrained beam (EX2)

SCI P387 advises a higher uniform load per meter under the ultimate condition (60.8 kN/m rather than 57.4 kN/m). This higher load is not transferred to the column in EX5, so Calcs.com ignores it. No SLS checks are conducted, although Calcs.com always shows the deflection checks.

Design the interior column (EX5)

Plan at level 1 from SCI P387 with the interior column at gridline G circled
Link the reactions from the joists on each side of the column at each floor. See Link Loads and Reactions Between Calculators.Because the project has a story height in Project Defaults, you can use it to set both the total column height and the distance between lateral restraints. Custom user formulas allow arithmetic, units and more in any input field. See Use Formulas and Convert Units in Inputs.
The interior column connecting each floor (excluding the roof) is designed in Calcs.com following the SCI P387 procedure. For details of the calculator, see Design a Steel Column to EN 1993 (Eurocode 3). Enter:
1

Geometry and steel grade

  • Steel grades: EN 10025-2 UK Prod Std, Gr. S275 (3 mm < t <= 16 mm), as for the joists.
  • Total column height: projectDefault("h_storey") * 3. This uses the story height from Project Defaults in a custom user formula to give the height of three stories.
  • Critical buckling lengths: projectDefault("h_storey"), the distance between each floor restraint.
  • Position of support from bottom: a fixed support at the bottom of the column. The floors do not provide lateral restraint.
2

Loads (EN 1991)

  • Axial, lateral and moment loads: link the reactions from the floor joists (EX1 and EX2) to each story of the column. You can link each reaction more than once, as the joists in each story carry the same load.
  • Default axial load eccentricity: set “Y-axis face” eccentricity, which by default applies the eccentricity 100 mm from the face of the flange, consistent with SCI P387. Only the Level 1 moment is checked. Because the ratio of column stiffnesses is less than 1.5, the design moment due to eccentricity is halved, by setting Axial Eccentricity = e_y/2.
  • Building category: Category “B: Office Areas”, as for the joists.
  • Self-weight: “No”.
3

Design criteria and National Annex parameters

  • All deflection limits come from Project Defaults.
  • Leave the partial factors and the factor for shear area at their defaults.
  • Buckling interaction: Annex A (less conservative, and recommended by the UK National Annex).
4

ULS: buckling resistance of uniform member in bending (EN 1993-1-1:2005 Cl 6.3.2)

  • Equivalent uniform moment factors C1C_1 and C2C_2: leave as 1 and 2 respectively, consistent with SCI P387.
Then check the key results in the summary section at the top right. No deflection check is conducted.

Analyze the roof truss (EX6)

Typical section from SCI P387 with the roof truss circled, spanning an 8 m and a 6 m bay
The Truss Analysis calculator accepts any truss dimensions: choose “Custom Truss” and enter the nodes and elements manually. Any member from the truss analysis can then be designed in the Steel Column calculator.
The roof truss spans between the exterior columns. See Analyze a Truss. Enter:
1

Truss geometry

  • Truss type: Custom Truss. The roof truss is similar to a simple fink truss (see Truss Types), but the bracing spacing differs slightly, so custom dimensions are entered.
2

Member selection

  • Chord and web members: 100 x 100 x 5 SHS for the chords and 70 x 70 x 5 SHS for the bracing members. The steel grade is not entered here, as it does not affect the deflections or forces in the structure.
3

Nodes, elements and supports

  • Nodes: enter the global x and y coordinates of each node, in any order.
  • Elements: enter each member and its type (1: Top Chord, 2: Web Member, 3: Bottom Chord).
  • Supports: a pinned support and a roller (Y restrained) at the start and end nodes, to model a simply supported truss.
4

Loads (EN 1991)

  • Include self-weight: “Yes”, as the total combined actions value of 7.32 kN/m does not include the SHS self-weight.
  • FEA point loads: FdF_d = 43.92 kN at all intermediate nodes, and half of FdF_d at each support node, consistent with SCI P387. Orientation is set to the global value (−90 degrees, vertical). Labels are not used.
The chord and web results can be designed for axial force only, by entering an axial force in a Steel Column calculation. Because the Steel Column calculator runs its own member analysis, a single governing moment or shear load cannot be assigned directly. In future, the results and dimensions of the member may be linked directly to the design calculator to prevent duplicating data. The Steel Column inputs are shown in EX5, so they are not repeated here.

Common questions

Yes. The strength load combinations (Eq 6.10a/b with ξ=0.925\xi = 0.925), the serviceability combinations, the frequent and quasi-permanent deflection limits, the steel grades and the buckling interaction method (Annex A) follow the UK National Annex.
Yes. The project follows the dimensions and loading of SCI P387 (Steel Building Design: Worked examples for students), so each member’s demand and capacity can be compared with the publication. Where the loading differs, the page says so.
The Steel Beam calculator for the floor joists (EX1 and EX2), the Steel Column calculator for the interior column (EX5) and the truss members (EX6), and the Truss Analysis calculator for the roof truss (EX6). Project Defaults and load linking tie them together.

Next steps

Design a Steel Beam to EN 1993 (Eurocode 3)

Design steel beams to EN 1993-1-1:2005 (Eurocode 3) with unlimited spans and loads. Checks bending, LTB, shear, web buckling and deflection.

Design a Steel Column to EN 1993 (Eurocode 3)

Design steel columns and studs to EN 1993-1-1:2005 (Eurocode 3). Checks axial compression, biaxial bending, interaction, LTB and deflection.

Analyze a Truss

Solve 2D roof, floor and custom trusses with a live FEA engine. Set nodes, fixities and members in the browser and see results as you work.

Project Defaults for Europe

A comprehensive guide to setting up project defaults for European design standards, including deflection limits, load combinations, and building geometry