Worked example
Symbols
The article uses these symbols, with the names the sheets use.Example 1: a fixed-roller beam under a uniform load
A 20 ft beam is fixed at the left end and on a roller at the right end. It carries one downward uniform load of 1 kip/ft over its full length. This one beam shows every sign in the Beam Analysis calculator: the load, the shear, a negative moment at the fixed support, a positive moment in the span, a downward deflection, and upward reactions with a moment reaction. The run is on Beam Analysis in a US customary project. The edits are:- Supports: Fixed at 0 ft and Roller at 20 ft
- Distributed Load: 1000 plf at the start and the end, from 0 ft to 20 ft (the default load is replaced)
Set the supports

Enter the load


Read the summary and the reactions

Read the graphs

Check the reactions per support

Inputs
Calcs.com output
Hand check
The reactions, the end moment and the peak span moment match the closed-form solution for a beam fixed at one end and simply supported at the other. This is a sanity check only. The deflection depends on the section and is not hand-checked. Beam Analysis.
Loads
A vertical load is entered as a positive number when it acts downward, and the load diagrams draw it as an arrow pointing down. This is the same in Beam Analysis, in the Wood Beam calculator and for the axial load on a column. The Wood Beam Loads panel draws a floor load and the self-weight as arrows pointing down.
Shear, moment and deflection
The shear, moment and deflection graphs follow the same rules in Beam Analysis (below the Summary) and in the Diagrams panel of the Wood Beam calculator.- Shear: under a downward load the shear is positive at the left support and negative at the right.
- Moment: a positive (sagging) moment plots above the axis, and a negative (hogging) moment plots below it. In Example 1, the fixed support gives a negative moment at that end.
- Deflection: a downward deflection is negative and plots below the axis.

Reactions
Support reactions that push up on the beam are positive. In Beam Analysis, the reactions diagram draws them as arrows pointing up, and for a fixed support it also draws the moment reaction as a curved arrow. In Example 1 the curved arrow reads counter-clockwise at the fixed end. When a reaction is linked to another calculator, the value is carried through as it appears in the reaction table, with no sign change. See Linking loads and reactions between calculators.Strong and weak axis
In the Wood Beam calculator, Member Orientation in Design Conditions chooses whether the member bends about the strong axis (X-X) or the weak axis (Y-Y). X-X is the axis with the higher moment of inertia. For the 5-1/2x16 24F-1.8E member in the Wood Beam screenshots, the strong axis moment of inertia is 1877 in⁴ and the weak axis is 222 in⁴.



Column loads and bracing
The Wood Column calculator measures positions up from the bottom of the column, and the diagram is labeled Distance from Bottom of Column (ft). Column loads are listed in the Axial, Lateral & Moment Loads table and entered in the Load Magnitudes window, opened with Edit… on a load row.





Common questions
Why is my deflection negative?
Why is my deflection negative?
Why is the moment negative at a fixed support?
Why is the moment negative at a fixed support?
Which axis is the strong axis?
Which axis is the strong axis?
Which way does a positive lateral load or moment point on a column?
Which way does a positive lateral load or moment point on a column?