Bushfire Attack Level
Run the calc- ‘Key Inputs’, where all of the required inputs are entered.
- ‘Advanced Parameter Overrides’, where advanced users may enter overrides for values used in the detailed (Appendix B) method, such as ambient temperature, flame width and emissivity, and elevation of the receiver.
- ‘Summary’, where the calculated Bushfire Attack Level is displayed, along with information about the design considerations that the given BAL requires. If a simplified method calculation is valid, then maximum distances to the vegetation for each BAL are also shown in tabular form.
- ‘Detailed Method Results’, where calculated values of interest to advanced users are displayed, including the forward rate of speed, flame angle, view factor, and radiant heat flux.
Method & scope
Symbols
These are the symbols shown in the calculator, with the label the app gives each one.Calculation method
The Bushfire Attack Level calculator determines BAL for a site per AS 3959:2018. BAL quantifies the radiant heat flux exposure from bushfire to which a building may be subjected, expressed as a level that maps directly to construction requirements.Simplified method (AS 3959:2018, Tables 2.4.2 and 2.4.3)
The simplified method looks up BAL from AS 3959:2018 Table 2.4.2 (for sites in FDI 80 fire weather regions) or Table 2.4.3 (for sites in FDI 100 fire weather regions). Inputs are:- FDI, Fire Danger Index for the region (80 or 100), derived from AS 3959:2018 Figure 1.5 or the relevant state government authority
- Vegetation class, Grassland, Scrub, Shrubland, Mallee/mulga/heath, Rainforest, or Forest
- Distance, horizontal distance in meters between the site and the nearest edge of classified vegetation
- Effective slope, slope under the vegetation in degrees (upslope increases fire intensity; downslope decreases it)
Detailed method (AS 3959:2018, Appendix B)
The detailed method calculates the radiant heat flux (kW/m²) at the site directly from fuel and weather parameters using the McArthur fire spread model:- Fuel age and fuel moisture content, derived from climate data or entered directly
- Wind speed at 10 m height, from the design fire weather scenario
- Ambient temperature and relative humidity, from the design weather event
- Fuel heat of combustion, for the vegetation type
BAL thresholds and construction requirements
How to use it
Open the calculator

Choose the calculation method

Select the Fire Danger Index

Check the low threat exclusion

Select the vegetation classification

Enter the distance and the slope


Set the site slope

Override the advanced parameters

Read the summary

Open a result to see its clause

Check the detailed method results
- Adjusted Forward Rate of Speed: The speed at which flames may advance on the site, adjusted for the Effective Slope. This is dependent upon many factors, including the type and quantity of fuel present, as well as climatic factors such as wind speed and humidity.
- Flame Length: The total length of the flame which may occur, dependent upon the type and quantity of fuel present, as well as the forward rate of speed.
- Flame Emissive Power: The energy power put out by a unit area of the flame, dependent primarily upon the flame temperature.
- Flame Angle: The angle at which the flame may form. This value is determined through an iterative solving process defined in the standard, and which may be referenced in the collapsed sections on the left side of the page.
- Maximum View Factor: This essentially refers to how much of the flame will be in direct ‘view’ of the site, and therefore how much of the flame’s heat will affect the site. It is found through the same iterative process as the Flame Angle.
- Elevation of Receiver: This value may be overridden manually, but if it is not, then the worst-case elevation is found through the same iterative process as the Flame Angle.
- Flame Path Length: The length along the ground which may be burning as the flame advances toward the site, dependent upon the Flame Angle, Flame Length, and Distance to Classified Vegetation.
- Atmospheric Transmissivity: The proportion of the flame’s heat which transmits through the atmosphere to the site. This value is based upon empirical testing and dependent upon the Ambient Temperature, Flame Temperature, Relative Humidity, and Path Length.
-
Radiant Heat Flux: The amount of heat which will reach the site, per unit area of the site. This value is compared with the various limits to determine the Bushfire Attack Level (for example, “BAL-29” means that up to 29 of heat flux will reach the site).

Common questions
What standard does this calculator follow?
What standard does this calculator follow?
What are the key inputs?
What are the key inputs?
What does the calculator output?
What does the calculator output?
What is the difference between the simplified and detailed methods?
What is the difference between the simplified and detailed methods?
What vegetation classifications are covered?
What vegetation classifications are covered?