# How to Enter Distributed Loads (Metric Units)

> How to Enter Distributed Loads (Metric Units)

In Calcs.com there is a designated table for Distributed Loads under the Loads section. This table is accompanied by a diagram of the structural component that is being analysed, which updates in real-time and indicates the loads you have entered.

<img src="https://mintcdn.com/clearcalcs/lchEzA4h00Mzlgpc/images/migrated/ef3291fd4c41-file-yhbfg2x2yn.png?fit=max&auto=format&n=lchEzA4h00Mzlgpc&q=85&s=2cadb2fb5e5b6f70f305acf2dcc2f0f7" alt="" width="596" height="416" data-path="images/migrated/ef3291fd4c41-file-yhbfg2x2yn.png" />

This article will discuss the input parameters in the Distributed Loads table and gives some worked examples on how to input distributed loads into Calcs.com for structural design applications.

# Input Parameters

<img src="https://mintcdn.com/clearcalcs/6PuU-K_D_MascHz6/images/migrated/c182eb7cd60a-file-ydmklzmo26.png?fit=max&auto=format&n=6PuU-K_D_MascHz6&q=85&s=264d1aa37ac1aa33ab4d6ca3d18ffed2" alt="" width="596" height="416" data-path="images/migrated/c182eb7cd60a-file-ydmklzmo26.png" />

| Parameter                   | Description                                                                                                                                                      |
| :-------------------------- | :--------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **Start Location (A)**      | The distance from the left end (zero point) of the beam where the load begins. Measured in millimetres.                                                          |
| **End Location (B)**        | The point where the load ceases to act, measured from the left end (zero point) of the beam. Measured in millimetres. Use **'L'** for the right end of the beam. |
| **Tributary Width (C & D)** | The width of the area from which the member obtains its load. See the explanation below for details.                                                             |
| **Load Magnitude (E)**      | The pressure magnitude, entered in kilopascals (kPa). Click the cell to open a table where you can select the load type and enter the value.                     |

<Tip>
  **Pro Tip:** You can enter conversion formulas directly into the cell (similar to Excel) for both Start and End locations.
</Tip>

<Tip>
  **Shortcut:** If the end location is the right end of the beam, you can input **'L'** instead of the actual length value.
</Tip>

## Understanding Tributary Width

Every structural element has an area from which it obtains its load. As with any other area, this can also be expressed as a product of length and width. The length of this area is usually either the length of the element itself or the length of the distributed load (B-A from the table). Tributary width is simply the width of this area.

To better illustrate this concept, consider a floor that is supported by members spaced 's' mm apart.

<img src="https://mintcdn.com/clearcalcs/XO7fzDjaQ7IYQ3qi/images/migrated/04162f107a2b-file-hwfwmozyjt.png?fit=max&auto=format&n=XO7fzDjaQ7IYQ3qi&q=85&s=e19947a0d65e3cafb2b882e2ac76808c" alt="" width="481" height="212" data-path="images/migrated/04162f107a2b-file-hwfwmozyjt.png" />

<Note>
  **Key Concept:** For most cases, the tributary width is the same as member spacing.
</Note>

Consider beam X, where its tributary area has the same length as the beam and the tributary width is 's'. Notice that the tributary area is not always a rectangle and can instead take on a triangular shape. In such instances:

* The starting and ending tributary widths will be different
* You'll need to enter different values for **Total Start Tributary Width** and **Total End Tributary Width**

Both tributary width values are measured in millimetres and refer to the width of the tributary area at the starting and ending points of the distributed load, respectively.

## Load Magnitudes

When you click on the Load Magnitudes cell, a new table will appear (see below).

<img src="https://mintcdn.com/clearcalcs/0BKfHfJWdoXOtU8o/images/migrated/da7fd22b4543-file-rindmiuppv.png?fit=max&auto=format&n=0BKfHfJWdoXOtU8o&q=85&s=87798b0576a04981e9589fdf0a11a246" alt="" width="644" height="383" data-path="images/migrated/da7fd22b4543-file-rindmiuppv.png" />

* **First Column:** A drop-down menu from which you can choose your load type.
* **Second Column:** You can input the magnitude of the load in kilopascals (kPa).

# Examples

## Example 1

### Task

Input a live load of 1.5kPa on a floor joist with a member spacing of 450mm.

### Method

<Steps>
  <Step title="Set the Range">
    Enter **0** for Start Location and **L** for End Location to apply the load to the full beam.
  </Step>

  <Step title="Define Tributary Width">
    Input the member spacing (**450mm**) into both the Start and End Tributary Width cells.
  </Step>

  <Step title="Apply Load Magnitude">
    Click the **Load Magnitudes** cell, select **Live Load** from the dropdown, and enter **1.5** in the magnitude field.
  </Step>
</Steps>

<img src="https://mintcdn.com/clearcalcs/XO7fzDjaQ7IYQ3qi/images/migrated/03da5be1909e-file-auce56yen0.png?fit=max&auto=format&n=XO7fzDjaQ7IYQ3qi&q=85&s=349cf9ea3e3c526ad41192bae00df83d" alt="" width="608" height="368" data-path="images/migrated/03da5be1909e-file-auce56yen0.png" />

<img src="https://mintcdn.com/clearcalcs/6PuU-K_D_MascHz6/images/migrated/c2fa2f764084-file-l1fuzhhvc2.jpg?fit=max&auto=format&n=6PuU-K_D_MascHz6&q=85&s=65d7a5378d26c7da4f32ef2811ab60bb" alt="" width="684" height="344" data-path="images/migrated/c2fa2f764084-file-l1fuzhhvc2.jpg" />

## Example 2

### Task

Input a dead load of 0.12kPa on a ceiling joist with a member spacing of 600mm.

### Method

<Steps>
  <Step title="Set the Range">
    Enter **0** for Start Location and **L** for End Location to apply the load to the full beam.
  </Step>

  <Step title="Define Tributary Width">
    Input the member spacing (**600mm**) into both the Start and End Tributary Width cells.
  </Step>

  <Step title="Apply Load Magnitude">
    Click the **Load Magnitudes** cell, select **Dead Load** from the dropdown, and enter **0.12** in the magnitude field.
  </Step>
</Steps>

<img src="https://mintcdn.com/clearcalcs/7GJyORIkCuwKrW7N/images/migrated/306595d1fb71-file-5tqeg4sutw.png?fit=max&auto=format&n=7GJyORIkCuwKrW7N&q=85&s=2ba4258953984cf2afedfc2d281c2973" alt="" width="620" height="368" data-path="images/migrated/306595d1fb71-file-5tqeg4sutw.png" />

<img src="https://mintcdn.com/clearcalcs/7GJyORIkCuwKrW7N/images/migrated/354f2f27591b-file-3hielk79gq.png?fit=max&auto=format&n=7GJyORIkCuwKrW7N&q=85&s=e8350e277b9acd5d4330318c698a14e1" alt="" width="682" height="346" data-path="images/migrated/354f2f27591b-file-3hielk79gq.png" />

## Example 3

### Task

Input a live load of 0.25kPa and a dead load of 0.9kPa on a rafter with 600mm member spacing.

### Method

<Steps>
  <Step title="Set the Range">
    Enter **0** for Start Location and **L** for End Location to apply the load to the full beam.
  </Step>

  <Step title="Define Tributary Width">
    Input the member spacing (**600mm**) into both the Start and End Tributary Width cells.
  </Step>

  <Step title="Apply Multiple Load Magnitudes">
    Click the **Load Magnitudes** cell to open the load table. Add two rows:

    * Select **Live Load** and enter **0.25** in the magnitude field
    * Select **Dead Load** and enter **0.9** in the magnitude field
  </Step>
</Steps>

<img src="https://mintcdn.com/clearcalcs/XO7fzDjaQ7IYQ3qi/images/migrated/0541ff207829-file-tvmfppcfd8.png?fit=max&auto=format&n=XO7fzDjaQ7IYQ3qi&q=85&s=c8c726dcb77c15e859d44877e2010409" alt="" width="619" height="368" data-path="images/migrated/0541ff207829-file-tvmfppcfd8.png" />

<img src="https://mintcdn.com/clearcalcs/lchEzA4h00Mzlgpc/images/migrated/ee09963486eb-file-hrhzj4dirt.png?fit=max&auto=format&n=lchEzA4h00Mzlgpc&q=85&s=71078f840bfefef3d4b52bf03a98781b" alt="" width="688" height="703" data-path="images/migrated/ee09963486eb-file-hrhzj4dirt.png" />